SUPERSEDED LCD Reference Article Article

Oxygen and Oxygen Equipment - Policy Article

A52514

Expand All | Collapse All
Draft Article
Draft Articles are works in progress and not necessarily a reflection of the current billing and coding practices. Revisions to codes are carefully and thoroughly reviewed and are not intended to change the original intent of the LCD.
Superseded
To see the currently-in-effect version of this document, go to the section.

Document Note

Note History

Contractor Information

Article Information

General Information

Source Article ID
N/A
Article ID
A52514
Original ICD-9 Article ID
Not Applicable
Article Title
Oxygen and Oxygen Equipment - Policy Article
Article Type
Article
Original Effective Date
10/01/2015
Revision Effective Date
04/01/2023
Revision Ending Date
N/A
Retirement Date
N/A

CPT codes, descriptions, and other data only are copyright 2023 American Medical Association. All Rights Reserved. Applicable FARS/HHSARS apply.

Fee schedules, relative value units, conversion factors and/or related components are not assigned by the AMA, are not part of CPT, and the AMA is not recommending their use. The AMA does not directly or indirectly practice medicine or dispense medical services. The AMA assumes no liability for data contained or not contained herein.

Current Dental Terminology © 2023 American Dental Association. All rights reserved.

Copyright © 2024, the American Hospital Association, Chicago, Illinois. Reproduced with permission. No portion of the AHA copyrighted materials contained within this publication may be copied without the express written consent of the AHA. AHA copyrighted materials including the UB‐04 codes and descriptions may not be removed, copied, or utilized within any software, product, service, solution, or derivative work without the written consent of the AHA. If an entity wishes to utilize any AHA materials, please contact the AHA at 312‐893‐6816.

Making copies or utilizing the content of the UB‐04 Manual, including the codes and/or descriptions, for internal purposes, resale and/or to be used in any product or publication; creating any modified or derivative work of the UB‐04 Manual and/or codes and descriptions; and/or making any commercial use of UB‐04 Manual or any portion thereof, including the codes and/or descriptions, is only authorized with an express license from the American Hospital Association. The American Hospital Association (the "AHA") has not reviewed, and is not responsible for, the completeness or accuracy of any information contained in this material, nor was the AHA or any of its affiliates, involved in the preparation of this material, or the analysis of information provided in the material. The views and/or positions presented in the material do not necessarily represent the views of the AHA. CMS and its products and services are not endorsed by the AHA or any of its affiliates.

CMS National Coverage Policy

N/A

Article Guidance

Article Text

NON-MEDICAL NECESSITY COVERAGE AND PAYMENT RULES
For any item to be covered by Medicare, it must 1) be eligible for a defined Medicare benefit category, 2) be reasonable and necessary for the diagnosis or treatment of illness or injury or to improve the functioning of a malformed body member, and 3) meet all other applicable Medicare statutory and regulatory requirements. Information provided in this policy article relates to determinations other than those based on Social Security Act §1862(a)(1)(A) provisions (i.e. “reasonable and necessary”) and Social Security Act §1834(a)(5)(E).

Oxygen and oxygen equipment is covered under the Durable Medical Equipment benefit (Social Security Act §1861(s)(6)). In order for a beneficiary’s equipment to be eligible for reimbursement the reasonable and necessary (R&N) requirements set out in the related Local Coverage Determination must be met. In addition, there are specific statutory payment policy requirements, discussed below, that also must be met.

REASONABLE USEFUL LIFETIME (RUL):

The reasonable useful lifetime for oxygen equipment is 5 years. The RUL is not based on the chronological age of the equipment. It starts on the initial date of service and runs for 5 years from that date.

RUL also does not take into account exchanges of equipment, new suppliers, or changes of modality (concentrator, gaseous, liquid).

Stationary and portable oxygen equipment is often provided at the same time therefore the RUL for both items runs concurrently. When the RUL of a beneficiary’s portable oxygen equipment differs from the RUL of the beneficiary’s stationary oxygen equipment, the RUL of the stationary oxygen equipment shall govern the application of RUL-based rules and processes for both types, stationary and portable, of oxygen equipment.

Until such time as the end date of the RUL of the stationary oxygen equipment is reached, the supplier must continue to furnish both the portable and stationary oxygen equipment.

  1. If the end date of the RUL of the portable oxygen equipment precedes the end date of the RUL of the stationary oxygen equipment, the end date of the RUL of the portable oxygen equipment is adjusted (extended) to coincide with the end date of the RUL of the stationary oxygen equipment.
  2. If the end date of the RUL of the portable oxygen equipment follows the end date of the RUL of the stationary oxygen equipment, the end date of the RUL of the portable oxygen equipment is adjusted (shortened) to coincide with the end date of the RUL of the stationary oxygen equipment.

When the end date of the RUL of the stationary oxygen equipment occurs, the beneficiary may elect to obtain replacement of both the stationary and the portable oxygen equipment.

If the beneficiary elects to obtain replacement of the stationary and the portable oxygen equipment, both types of oxygen equipment must be replaced at the same time.

When the stationary and the portable oxygen equipment are replaced, a new 36-month rental period and new RUL is started for both the replacement stationary oxygen equipment and the replacement portable oxygen equipment.

Beginning January 1, 2011, a beneficiary who resides in a DMEPOS competitive bidding area (CBA) may obtain replacement of both the stationary and portable oxygen systems only from a contract supplier having a competitive bidding contract for the CBA in which the beneficiary permanently resides.

A grandfathered supplier for oxygen and other grandfathered equipment as of January 1, 2011, who has continued to furnish such equipment that has not yet reached the 36-month rental cap, does not qualify to furnish replacement equipment once the end date of the RUL of the stationary equipment is reached, if the beneficiary resides in the CBA when the end of the RUL has been reached, unless the status of the grandfathered supplier has changed to a contract supplier for the current round of the competitive bidding program.

OXYGEN EQUIPMENT:

Initial 36 months

Reimbursement for oxygen equipment is limited to 36 monthly rental payments. Payment for accessories (e.g., cannula, tubing, etc.), delivery, back-up equipment, maintenance, and repairs is included in the rental allowance. Payment for oxygen contents (stationary and/or portable) is included in the allowance for stationary equipment (E0424, E0439, E1390, E1391).

Payment for stationary equipment is increased for beneficiaries requiring greater than 4 liters per minute (LPM) of oxygen flow and decreased for beneficiaries requiring less than 1 LPM. If a beneficiary qualifies for additional payment for greater than 4 LPM of oxygen and also meets the requirements for portable oxygen, the appropriate modifiers (QB or QF) must be used.

The supplier who provides oxygen equipment for the first month must continue to provide any necessary oxygen equipment and all related items and services through the 36-month rental period, unless one of the following exceptions is met:

  • Beneficiary relocates temporarily or permanently outside of the supplier’s service area
  • Beneficiary elects to obtain oxygen from a different supplier
  • Individual case exceptions made by CMS or DME MAC
  • Item becomes subject to competitive bidding

Providing different oxygen equipment/modalities (e.g., concentrator [stationary or portable], gaseous, liquid, trans-filling equipment) is not permitted unless one of the following requirements is met:

  • Supplier replaces the equipment with the same or equivalent item
  • Treating practitioner’s orders different equipment
  • Beneficiary chooses to receive an upgrade and signs an Advance Beneficiary Notice of Non-coverage (ABN)
  • CMS or the DME MAC determines that a change in equipment is warranted

A new 36-month rental period can begin only in the following situations:

  • Specific incident of damage beyond repair (e.g., dropped and broken, fire, flood, etc.) or the item is stolen or lost
  • Break-in-need for at least 60 days plus the days remaining in the month of discontinuation and new medical necessity is established (see “BREAK-IN-SERVICE” below)

A new 36-month rental period does not start in the following situations:

  • Replacing equipment due to malfunction, wear and tear, routine maintenance, repair
  • Providing different equipment based on a treating practitioner order or beneficiary request for an upgrade
  • Break-in-need less than 60 days plus the days remaining in the month of discontinuation (see “BREAK-IN-SERVICE” below)
  • Break-in-billing (see “BREAK-IN-SERVICE” below)
  • Changing suppliers

Months 37-60

There is no further payment for oxygen equipment during the 5-year reasonable useful lifetime (RUL) of the equipment after 36 rental payments have been made. If use of portable equipment (E0431, E0433, E0434, E1392, K0738) begins after the use of stationary equipment begins, payment for the portable equipment can continue after payment for the stationary equipment ends until 36 rental payments have been made for the portable equipment.

For information on payment for contents and maintenance, see separate sections below.

The supplier who provided the equipment during the 36th rental month is required to continue to provide the equipment, accessories, contents (if applicable), maintenance, and repair of the oxygen equipment during the 5 year reasonable useful lifetime of the equipment.

Rules for providing different equipment/modalities are the same in months 37-60 as they are in the initial 36 months (see above).

A new 36-month rental period can begin only in the following situation:

  • There is a specific incident of damage beyond repair (e.g., dropped and broken, fire, flood, etc.) or the item is stolen or lost

A new 36-month rental period does not start in the following situations:

  • Replacing equipment due to malfunction, wear and tear, routine maintenance, repair
  • Providing different equipment based on a treating practitioner order or beneficiary request for an upgrade
  • Break-in-need (see “BREAK-IN-SERVICE” below)
  • Break-in-billing (see “BREAK-IN-SERVICE” below)
  • Changing suppliers

Months 61 and after

At any time after the end of the 5-year reasonable useful lifetime for oxygen equipment, the beneficiary may elect to receive new equipment, thus beginning a new 36-month rental period.

If the beneficiary elects not to receive new equipment after the end of the 5-year reasonable useful lifetime and if the supplier retains title to the equipment, all elements of the payment policy for months 37-60 remain in effect. There is no separate payment for accessories or repairs. If the beneficiary was using gaseous or liquid oxygen equipment during the 36th rental month, payment can continue to be made for oxygen contents.

If the beneficiary elects not to receive new equipment after the end of the 5-year reasonable useful lifetime and if the supplier transfers title of the equipment to the beneficiary, accessories, maintenance, and repairs are statutorily non-covered by Medicare. Contents are separately payable for beneficiary-owned gaseous or liquid systems.

If a beneficiary enters Medicare FFS with beneficiary-owned equipment, accessories, maintenance, and repairs are statutorily non-covered by Medicare. Contents are separately payable for beneficiary-owned gaseous or liquid systems.

OXYGEN CONTENTS:

Payment for stationary and portable contents is included in the fee schedule allowance for stationary equipment. No payment can be made for oxygen contents in a month in which payment is made for stationary equipment.

If the beneficiary was using stationary gaseous or liquid oxygen equipment during the 36th rental month, payment for stationary contents (E0441 or E0442) begins when the rental period for the stationary equipment ends.

If the beneficiary was using portable gaseous or liquid equipment during the 36th rental month of stationary equipment (gaseous, liquid, or concentrator), payment for portable contents (E0443, E0444 or E0447) begins when the rental period for the stationary equipment ends. If the beneficiary began using portable gaseous or liquid equipment after starting on stationary equipment, payment for the portable equipment would continue until the end of the 36-month rental period for that equipment even though payment was also being made for the portable contents.

If the beneficiary was using both stationary and portable gaseous or portable equipment during the 36th rental month of stationary equipment, payment for both stationary contents (E0441 or E0442) and portable contents (E0443, E0444 or E0447) begins when the rental for the stationary equipment ends.

If the beneficiary is using only portable gaseous or liquid equipment and not stationary equipment during months 1 through 36 of the portable equipment rental, payment for portable contents begins when the rental period for the portable equipment begins. If stationary equipment is subsequently added, separate payment for portable contents ends because payment for contents is included in the payment for stationary equipment.

If the beneficiary was not using gaseous or liquid equipment (stationary or portable) in the 36th month, but was subsequently switched to gaseous or liquid oxygen based on a treating practitioner order, contents may be paid.

If the beneficiary has a stationary concentrator, portable liquid equipment, and a stationary liquid tank to fill the portable cylinders, when payment for contents begins, payment will only be made for portable liquid contents.

Suppliers must provide whatever quantity of oxygen contents are needed for a beneficiary’s activities both inside and outside the home.

A maximum of 3 months of oxygen contents may be delivered at any one time. (Refer to Billing Information section [below] for additional information concerning billing oxygen contents.)

There is no difference in payment for oxygen contents for beneficiaries receiving more than 4 LPM or less than 1 LPM.

No more than 1 unit of service (UOS) for stationary contents and/or 1 UOS for portable contents per month are billable.

Refer to the Coverage Indications, Limitations and/or Medical Necessity section of the LCD for additional information about refills of oxygen contents.

MAINTENANCE OF EQUIPMENT:

Initial 36 months

There is no separate payment for maintenance and servicing (M&S).

Months 37 through 60

If a beneficiary was using a stationary concentrator, portable concentrator, or trans-filling equipment during the 36th rental month, Medicare will pay for an M&S visit no more often than every 6 months, beginning no sooner than 6 months following the end of the rental period. If the equipment is covered under a warranty that covers labor related to routine/general maintenance and servicing (e.g., inspection, changing filters, cleaning, and calibration), payment for the first M&S visit can be no sooner than 6 months following the end of that warranty.

A supplier must actually make a visit to bill the service. If multiple M&S visits are made during a 6 month period, only one will be paid.

There is no M&S payment for gaseous or liquid equipment.

Month 61 and after

If the beneficiary elects not to replace a concentrator or trans-filling equipment and if the supplier retains title to the equipment, coverage for M&S is the same as in months 37-60.

If the beneficiary elects not to replace a concentrator or trans-filling equipment and if the supplier transfers title to the beneficiary, M&S is statutorily non-covered.

OXYGEN ACCESSORIES:

Accessories, including but not limited to, trans-tracheal catheters (A4608), cannulas (A4615), tubing (A4616), mouthpieces (A4617), face tent (A4619), masks (A4620, A7525), oxygen conserving devices (A9900), oxygen tent (E0455), humidifiers (E0555), nebulizer for humidification (E0580), regulators (E1353), and stand/rack (E1355) are included in the allowance for rented oxygen equipment. The supplier must provide any accessory ordered by the treating practitioner. Accessories used with beneficiary-owned oxygen equipment will be denied as non-covered.

RELOCATION and TRAVEL:

Months 1 through 36

If the beneficiary relocates outside the supplier’s service area (either short-term travel, extended temporary relocation, or permanent relocation), then for the remainder of the rental month for which it billed, the home supplier is required to provide the equipment and related items/service itself or make arrangements with a different supplier to provide the equipment, items, and services. For subsequent rental months that the beneficiary is outside the service area, the home supplier is encouraged to either provide the equipment and related items/services itself or assist the beneficiary in finding another supplier in the new location. The home supplier may not bill for or be reimbursed by Medicare if it is not providing oxygen equipment or has not made arrangements with a different supplier to provide the equipment on the anniversary billing date. Medicare will pay only one supplier to provide oxygen during any one-rental month.

Months 37 through 60

If the beneficiary relocates outside the supplier’s service area (either short-term travel, extended temporary relocation, or permanent relocation), the home supplier is required to either provide the equipment and related items/services itself or make arrangements with a different supplier to provide the equipment and related items/services.

Miscellaneous

Oxygen services furnished by an airline to a beneficiary are non-covered. Payment for oxygen furnished by an airline is the responsibility of the beneficiary and not the responsibility of the supplier.

Medicare does not cover items or services provided/used outside the United States and its territories. The supplier is not required to provide or arrange for oxygen use in those situations.

BREAK-IN-SERVICE:

  • Break-in-billing/Part B payment without break-in-medical necessity
    • If beneficiary enters hospital or SNF or joins Medicare HMO and continues to need/use oxygen, when beneficiary returns home or rejoins Medicare FFS, payment resumes where it left off
  • Break-in-medical necessity (break-in-need)
    • If need/use of oxygen ends for less than 60 days plus the remainder of the rental month of discontinuation and then resumes, payment resumes where it left off
    • During the 36-month rental period, if need/use of oxygen ends for more than 60 days plus the remainder of the rental month of discontinuation and new medical necessity is established, a new 36 month rental period would begin
    • During months 37-60, if need/use of oxygen ends for more than 60 days plus the remainder of the rental month of discontinuation and new medical necessity is established, a new rental period does not begin. The supplier who provided the oxygen equipment during the 36th rental month must provide all necessary items and services for the duration of the reasonable useful lifetime.

MISCELLANEOUS:

Only rented oxygen equipment is eligible for coverage. Purchased oxygen equipment is statutorily non-covered.

Oximeters (E0445) and replacement probes (A4606) will be denied as non-covered because they are monitoring devices that provide information to the treating practitioner to assist in managing the beneficiary’s treatment.

Respiratory therapist services are non-covered under the DME benefit.

REQUIREMENTS FOR SPECIFIC DMEPOS ITEMS PURSUANT TO Final Rule 1713 (84 Fed. Reg Vol 217)

Final Rule 1713 (84 Fed. Reg Vol 217) requires a face-to-face encounter and a Written Order Prior to Delivery (WOPD) for specified HCPCS codes. CMS and the DME MACs provide a list of the specified codes, which is periodically updated. The required Face-to-Face Encounter and Written Order Prior to Delivery List is available here.

Claims for the specified items subject to Final Rule 1713 (84 Fed. Reg Vol 217) that do not meet the face-to-face encounter and WOPD requirements specified in the LCD-related Standard Documentation Requirements Article (A55426) will be denied as not reasonable and necessary.

If a supplier delivers an item prior to receipt of a WOPD, it will be denied as not reasonable and necessary. If the WOPD is not obtained prior to delivery, payment will not be made for that item even if a WOPD is subsequently obtained by the supplier. If a similar item is subsequently provided by an unrelated supplier who has obtained a WOPD, it will be eligible for coverage.

POLICY SPECIFIC DOCUMENTATION REQUIREMENTS

In addition to policy specific documentation requirements, there are general documentation requirements that are applicable to all DMEPOS policies. These general requirements are located in the DOCUMENTATION REQUIREMENTS section of the LCD.

Refer to the LCD-related Standard Documentation Requirements article, located at the bottom of this Policy Article under the Related Local Coverage Documents section for additional information regarding GENERAL DOCUMENTATION REQUIREMENTS and the POLICY SPECIFIC DOCUMENTATION REQUIREMENTS discussed below.

DOCUMENTATION REQUIREMENTS FOR INITIAL CLAIMS FOR OXYGEN

Documentation for initial coverage requires information in the medical record showing:

  • Evidence of qualifying test results at the time of need; and,
  • Evidence of an evaluation of the qualifying test results by a treating practitioner

In order to provide initial coverage for beneficiaries in Groups I, II and III, there must be evidence in the medical record documenting one of the following A-C criteria:

  1. A symptomatic, hypoxemic patient who meets criteria for Group I or II; or,
  2. A symptomatic, normoxemic patient with a medical condition that improves with oxygen therapy; or,
  3. For beneficiaries with concurrent Obstructive Sleep Apnea (OSA), the qualifying oxygen saturation test is performed following optimal treatment of the OSA as described in the Coverage Indications, Limitations and/or Medical Necessity.

DOCUMENTATION FOR CONTINUED PAYMENT OF OXYGEN AFTER INITIAL COVERAGE

In order to continue payment of oxygen and oxygen equipment claims, there must be evidence in the medical record documenting:

Group I

While there is no formal requirement for re-evaluation and retesting, providers should ensure that once qualified for home oxygen therapy, the oxygen therapy and oxygen equipment remain reasonable and necessary pursuant to Social Security Act §1862 (a)(1)(A).

Group II

  1. Evaluation and documentation of a repeat qualifying blood gas test by the treating practitioner between the 61st and 90th days after initiation of therapy pursuant to Social Security Act §1834(a)(5)(E); and,
  2. A new SWO by the treating practitioner.

Group III

  1. Evaluation and documentation of a repeat, normoxemic, qualifying blood gas test by the treating practitioner between the 61st and 90th days after initiation of therapy, pursuant to National Coverage Determination (NCD) 240.2 and Social Security Act §1834(a)(5)(E); and,
  2. A new SWO by the treating practitioner.

Reimbursement ends unless these continued payment and documentation requirements are met. At such time that these continued payment and documentation requirements are met, payment will resume at the month in the rental cycle where the rental was stopped. A new, initial rental cycle does not begin when the continued payment documentation requirements are met. 

REPAIRS:

The supplier must maintain detailed records describing the need for and nature of all repairs including a detailed explanation of the justification for any component or part replaced as well as the labor time to restore the item to its functionality.

REPLACEMENT EQUIPMENT:

Claims for the initial rental month (and only the initial rental month) must have the RA modifier (Replacement of DME item) added to the HCPCS code for the equipment when there is replacement due to reasonable useful lifetime or replacement due to damage, theft, or loss.

Claims for the initial rental month must include a narrative explanation of the reason why the equipment was replaced and supporting documentation must be maintained in the supplier's files.

A treating practitioner’s order is needed to reaffirm the medical necessity of the item for replacement of an item.

MODIFIERS

GA, GY, GZ, KX, N1, N2 and N3 MODIFIERS:

For oxygen claims covered by Medicare prior to April 1, 2023, suppliers may continue to use the KX modifier or may use the N-modifiers for claims with dates of service on or after April 1, 2023.

For initial claims for oxygen or new 36-month oxygen rental periods with dates of service on or after April 1, 2023, suppliers must use the N1, N2 or N3 modifier as described below:

  • N1 modifier only if all of the criteria in the Coverage Indications, Limitations and/or Medical Necessity section of the related LCD have been met for Group I beneficiaries.
  • N2 modifier only if all of the criteria in the Coverage Indications, Limitations and/or Medical Necessity section of the related LCD have been met for Group II beneficiaries.
  • N3 modifier only if all of the criteria in the Coverage Indications, Limitations and/or Medical Necessity section of the related LCD have been met for Group III beneficiaries.

For initial claims for oxygen or new 36-month oxygen rental periods with dates of service on or after April 1, 2023, submitted with the KX modifier will be rejected for invalid modifier.

If all of the criteria in the Coverage Indications, Limitations and/or Medical Necessity section have not been met, the GA, GY or GZ modifier must be added to the code. When there is an expectation of a medical necessity denial, suppliers must enter GA modifier on the claim line if they have obtained a properly executed Advance Beneficiary Notice (ABN), a GZ modifier if they have not obtained a valid ABN, or a GY modifier if the item or service is statutorily excluded.

Depending on the claim date of service described above, claim lines billed without a GA, GY, GZ, KX, N1, N2 or N3 modifier will be rejected as missing information.

QA, QB, QE, QF, QG and QR MODIFIERS:

42 CFR Section 414.226(e) stipulates:

  1. If prescribed flow rate is different for stationary versus portable, the flow rate for stationary is used.
  2. If prescribed flow rate is different for the patient at rest versus the patient with exercise, the flow rate at rest is used.
  3. If prescribed flow rate is different for nighttime versus daytime use, the flow rates are averaged.

QA: For scenarios where the beneficiary has different daytime and nighttime oxygen flow requirements. Used if the average documented flow requirement from a daytime “at rest” qualifying test and flow rate for nocturnal oxygen requirement (standard arithmetic rounding rules apply) is <1 LPM.

QB: For scenarios where the beneficiary has different daytime and nighttime oxygen flow requirements. Used if the average documented flow requirement from a daytime “at rest” qualifying test and flow rate for nocturnal oxygen requirement (standard arithmetic rounding rules apply) is >4 LPM, and portable oxygen is prescribed.

QE: Used if the documented flow requirement on an “at rest” qualifying test is <1 LPM.

QF: Used if the documented flow requirement on an “at rest” qualifying test is >4 LPM, and portable oxygen is prescribed. DO NOT use a flow requirement from a “with exercise” qualifying test.

QG: Used if the documented flow requirement on an “at rest” qualifying test is >4 LPM. DO NOT use a flow requirement from a “with exercise” qualifying test.

QR: For scenarios where the beneficiary has different daytime and nighttime oxygen flow requirements. Used if the average documented flow requirement from a daytime “at rest” qualifying test and flow rate for nocturnal oxygen requirement (standard arithmetic rounding rules apply) is >4 LPM.

CODING GUIDELINES

The appropriate modifier must be used if the prescribed flow rate is less than 1 LPM (QA or QE) or greater than 4 LPM (QG or QR).

For claims with dates of service on or after 04/01/2018 the modifier QB or QF should be used in conjunction with claims submitted for stationary oxygen (codes E0424, E0439, E1390, or E1391) and portable oxygen (codes E0431, E0433, E0434, E1392, or K0738) when the prescribed amount of oxygen is greater than 4 liters per minute (LPM).

HCPCS code E1391 (Oxygen concentrator, dual delivery port) is used in situations in which two beneficiaries are both using the same concentrator. In this situation, this code should only be billed for one of the beneficiaries.

HCPCS codes E1405 and E1406 describe oxygen and water vapor enriching systems with or without heated delivery respectively. These devices both extract oxygen from the surrounding air (similar to an oxygen concentrator) and add humidification. They require substantially higher oxygen flow rates in order to deliver the same concentration of oxygen as that achieved by standard oxygen delivery systems (for example, concentrators or liquid/gaseous systems). Since codes E1405 and E1406 require a higher flow rate but do not provide a benefit to the beneficiary in terms of the inspired concentration of oxygen, modifiers QB, QF, QG, and QR, which are appended to claim lines to indicate oxygen flow rates greater than 4 liters/minute, must not be used with codes E1405 and E1406.

HCPCS code E1392 describes an oxygen concentrator which is designed to be portable, is capable of delivering 85% or greater oxygen concentration, and is capable of operating on either AC or DC (e.g., auto accessory outlet) power. Code E1392 includes the device itself, an integrated battery or beneficiary-replaceable batteries that are capable of providing at least 2 hours of remote portability at a minimum of 2 LPM equivalency, a battery charger, an AC power adapter, a DC power adapter, and a carry bag and/or cart. The combined weight of the concentrator and the battery/batteries capable of 2 hours of portability must be 20 pounds or less. If a concentrator meets all of these criteria and is also capable of functioning as a stationary concentrator, operating 24 hours per day, 7 days per week, the stationary concentrator code (E1390) is billed in addition to code E1392.

HCPCS code K0738 describes a feature of an oxygen concentrator that allows the beneficiary to fill portable gaseous oxygen cylinders from a stationary concentrator. This feature may be integrated into the stationary concentrator or be a separate component. When code K0738 is billed, code E0431 (portable gaseous oxygen system, rental) must not be used.

HCPCS code E0433 describes a feature of an oxygen concentrator that allows the beneficiary to fill portable liquid oxygen cylinders from a stationary concentrator. This feature may be integrated into the stationary concentrator or be a separate component. When code E0433 is billed, code E0434 (portable liquid oxygen system, rental) must not be used.

HCPCS code E1352 (OXYGEN ACCESSORY, FLOW REGULATOR CAPABLE OF POSITIVE INSPIRATORY PRESSURE) provides positive pressure inspiratory support for patients using oxygen. This product consists of multiple components - control unit, flow regulator, connecting hose and nasal interface (pillows). E1352 is an all-inclusive code for this product that includes all components.

HCPCS code E0467 (HOME VENTILATOR, MULTI-FUNCTION RESPIRATORY DEVICE, ALSO PERFORMS ANY OR ALL OF THE ADDITIONAL FUNCTIONS OF OXYGEN CONCENTRATION, DRUG NEBULIZATION, ASPIRATION, AND COUGH STIMULATION, INCLUDES ALL ACCESSORIES, COMPONENTS AND SUPPLIES FOR ALL FUNCTIONS) describes a ventilator that integrates the function of multiple types of equipment into a single device. Code E0467 combines the function of a ventilator with all of the following:

  • Oxygen equipment
  • Nebulizer and compressor
  • Aspirator (suction device)
  • Cough stimulator (multiple products)

If the multifunction ventilator does not include all of the functions listed above, then the ventilator must not be coded as E0467. Multifunction ventilators that combine some but not all, of the listed functions, must be coded as E1399 (DURABLE MEDICAL EQUIPMENT, MISCELLANEOUS).

Positive airway pressure (PAP) devices, respiratory assist devices (RAD), and custom fabricated oral appliances, are considered same or similar to the features of products coded E0467.

The following oxygen and oxygen equipment HCPCS codes for individual items are included in the functionality of code E0467:

  • HCPCS codes E0424, E0431, E0433, E0434, E0439, E0441, E0442, E0443, E0444, E0447, E1390, E1391, E1392, E1405, E1406 and K0738

For E0467 claims with dates of service before April 3, 2020:

Claims for any of the HCPCS codes listed above that are submitted on the same claim or that overlap any date(s) of service for E0467 is considered to be unbundling.

In addition, any claim for repair (HCPCS code K0739 for labor and any HCPCS code for replacement items) of beneficiary-owned equipment identified by HCPCS codes listed above is considered as unbundling if the date(s) of service for the repair overlaps any date(s) of service for code E0467.

Claims for code E0467 with a date(s) of service that overlaps date(s) of service for any of the following scenarios are considered as a claim for same or similar equipment when the beneficiary:

  • Is currently in a rental month for any of the items listed above
  • Owns any of the equipment listed above that has not reached the end of its reasonable useful lifetime.
  • Has oxygen equipment that reached the 36-month rental but has not reached the end of its reasonable useful lifetime.

For E0467 claims with dates of service on or after April 3, 2020:

Any claim for repair (HCPCS code K0739 for labor and any HCPCS code for replacement items) of beneficiary-owned equipment identified by HCPCS codes listed above is considered as unbundling if the date(s) of service for the repair overlaps any date(s) of service for code E0467.

Claims for code E0467 with a date(s) of service that overlaps date(s) of service in a rental month for any of the items listed above are considered as a claim for same or similar equipment.

CODING VERIFICATION REVIEW

The only products which may be billed using the following list of HCPCS codes are those for which a written coding verification review (CVR) has been made by the PDAC contractor and subsequently published on the Product Classification List (PCL). Information concerning the documentation that must be submitted to the PDAC for a CVR can be found on the PDAC website or by contacting the PDAC. A PCL with products which have received a coding verification can be found on the PDAC website. The effective date of the CVR is included for each code.

Effective for claims with dates of service on or after January 1, 2006:

E1405

E1406

Effective for claims with dates of service on or after January 1, 2022:

E0467

If a product is billed to Medicare using a HCPCS code that requires written CVR, but the product is not on the PCL for that particular HCPCS code, then the claim line will be denied as incorrect coding.

Suppliers should contact the Pricing, Data Analysis, and Coding (PDAC) contractor for guidance on the correct coding of these items.

BILLING INFORMATION

When billing oxygen contents (refer to the Policy Article, Non-Medical Necessity Coverage and Payment Rules section), suppliers should use a date of service (DOS) that is the anniversary date of the equipment whose rental period has ended. The billed DOS will usually not be the actual delivery date. The supplier must have a delivery slip for the actual delivery date.

A supplier does not have to deliver contents every month in order to bill every month. In order to bill for contents, the supplier must have previously delivered quantities of oxygen that are expected to be sufficient to last for one month following the DOS on the claim. Suppliers should monitor usage of contents. Billing may continue on a monthly basis as long as sufficient supplies remain to last for one month as previously described. If there are insufficient contents to be able to last for a month additional contents should be provided.

Suppliers may bill a flat rate for contents each month. The submitted charges do not have to vary with the quantity of tanks delivered.

Claims for oxygen contents and/or oxygen accessories should not be submitted in situations in which they are not separately payable.

Response To Comments

Number Comment Response
1
N/A

Coding Information

Bill Type Codes

Code Description

Please accept the License to see the codes.

N/A

Revenue Codes

Code Description

Please accept the License to see the codes.

N/A

CPT/HCPCS Codes

Please accept the License to see the codes.

N/A

CPT/HCPCS Modifiers

Group 1

Group 1 Paragraph

N/A

Group 1 Codes

N/A

N/A

ICD-10-CM Codes that Support Medical Necessity

Group 1

Group 1 Paragraph

N/A

Group 1 Codes

N/A

N/A

ICD-10-CM Codes that DO NOT Support Medical Necessity

Group 1

Group 1 Paragraph

N/A

Group 1 Codes

N/A

N/A

ICD-10-PCS Codes

Group 1

Group 1 Paragraph

N/A

Group 1 Codes

N/A

N/A

Additional ICD-10 Information

N/A

Bill Type Codes

Contractors may specify Bill Types to help providers identify those Bill Types typically used to report this service. Absence of a Bill Type does not guarantee that the article does not apply to that Bill Type. Complete absence of all Bill Types indicates that coverage is not influenced by Bill Type and the article should be assumed to apply equally to all claims.

Code Description

Please accept the License to see the codes.

N/A

Revenue Codes

Contractors may specify Revenue Codes to help providers identify those Revenue Codes typically used to report this service. In most instances Revenue Codes are purely advisory. Unless specified in the article, services reported under other Revenue Codes are equally subject to this coverage determination. Complete absence of all Revenue Codes indicates that coverage is not influenced by Revenue Code and the article should be assumed to apply equally to all Revenue Codes.

Code Description

Please accept the License to see the codes.

N/A

Other Coding Information

Group 1

Group 1 Paragraph

N/A

Group 1 Codes

N/A

N/A

Coding Table Information

Excluded CPT/HCPCS Codes - Table Format
Code Descriptor Generic Name Descriptor Brand Name Exclusion Effective Date Exclusion End Date Reason for Exclusion
N/A N/A
N/A
Non-Excluded CPT/HCPCS Ended Codes - Table Format
Code Descriptor Generic Name Descriptor Brand Name Exclusion Effective Date Exclusion End Date Reason for Exclusion
N/A

Revision History Information

Revision History Date Revision History Number Revision History Explanation
04/01/2023 R14

Revision Effective Date: 04/01/2023
DOCUMENTATION FOR CONTINUED PAYMENT OF OXYGEN AFTER INITIAL COVERAGE:
Revised: Documentation requirements for Group II and Group III to remove re-evaluation and specify documentation of testing requirements (effective 09/27/2021)
MODIFIERS:
Added: N1, N2 and N3 modifier instructions
Revised: Direction regarding the use of the KX modifier on or after April 1, 2023

02/23/2023: At this time the 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

01/01/2023 R13

Revision Effective Date: 01/01/2023
NON-MEDICAL NECESSITY COVERAGE AND PAYMENT RULES:
Added: Reference to Social Security Act §1834(a)(5)(E)
POLICY SPECIFIC DOCUMENTATION REQUIREMENTS:
Removed: References to chronic stable state (effective 09/27/2021)
Revised: Documentation requirements to align with information in the Coverage Indications, Limitations, and/or Medical Necessity section of the related Oxygen and Oxygen Equipment LCD (effective 09/27/2021)
Removed:
”LONG TERM OXYGEN THERAPY TRIALS (LTOT)” section and related information (effective 09/27/2021)
Removed: "
CLUSTER HEADACHES” section and related information (effective 09/27/2021)
REPLACEMENT EQUIPMENT:
Removed: References to "Recertification" and "Certification of Medical Necessity"
CERTIFICATE OF MEDICAL NECESSITY (CMN):
Removed: Section and related information
CODING GUIDELINES:
Removed: Clinical trial information for cluster headaches
ICD-10-CM CODES THAT SUPPORT MEDICAL NECESSITY: 
Removed: Group 1 Paragraph information 
Removed: ICD-10-CM codes from Group 1 Codes
Removed: Group 2 Paragraph information
Removed: ICD-10-CM code from Group 2 Codes
ICD-10-CM CODES THAT DO NOT SUPPORT MEDICAL NECESSITY:
Removed: Group 1 Paragraph information

11/17/2022: At this time the 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

08/02/2020 R12

Revision Effective Date: 08/02/2020
REQUIREMENTS FOR SPECIFIC DMEPOS ITEMS PURSUANT TO FINAL RULE 1713 (84 FED. REG VOL 217):
Removed: “The link will be located here once it is available.”
Added: “The required Face-to-Face Encounter and Written Order Prior to Delivery List is available here.” with a hyperlink to the list

04/14/2022: At this time the 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

08/02/2020 R11

Revision Effective Date: 08/02/2020
CODING GUIDELINES:
Moved: E1405 and E1406 coding verification review (CVR) language to coding verification review section
Revised: Coding instructions for multifunction ventilators (E0467) (Effective 01/01/2019)
CODING VERIFICATION REVIEW:
Added: Section header and PDAC CVR information
Added: CVR requirement for products coded E1405, E1406 and E0467

11/11/2021: At this time the 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

08/02/2020 R10

Revision Effective Date: 08/02/2020
CODING GUIDELINES:
Revised: Guidance for billing HCPCS code E0467 (Effective April 3, 2020)

08/13/2020: At this time 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

08/02/2020 R9

Revision Effective Date: 08/02/2020
NON-MEDICAL NECESSITY COVERAGE AND PAYMENT RULES:
Revised: “physician” to “treating practitioner”
REQUIREMENTS FOR SPECIFIC DMEPOS ITEMS PERSUANT TO 42 CFR 410.38(g):
Removed: Section removed
REQUIREMENTS FOR SPECIFIC DMEPOS ITEMS PURSUANT TO FINAL RULE 1713 (84 Fed. Reg Vol 217):
Added: Section and related information based on Final Rule 1713
POLICY SPECIFIC DOCUMENTATION REQUIREMENTS:
Revised: “physician” to “treating practitioner”
CERTIFICATE OF MEDICAL NECESSITY (CMN):
Revised: “physician” to “treating practitioner”
Revised: “detailed written order” to “standard written order”
Removed: Outdated CMN Form number
ICD-10 CODES THAT SUPPORT MEDICAL NECESSITY:
Revised: Section header “ICD-10 Codes that are Covered” updated to “ICD-10 Codes that Support Medical Necessity”
ICD-10 CODES THAT DO NOT SUPPORT MEDICAL NECESSITY:
Revised: Section header “ICD-10 Codes that are Not Covered” updated to “ICD-10 Codes that DO NOT Support Medical Necessity”

06/18/2020: At this time 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

01/01/2019 R8

Revision Effective Date: 01/01/2019
CODING GUIDELINES:
Revised: E0467 Coding Guidelines to include custom fabricated oral appliances
Added: E0447, E1405, and E1406 to HCPCS codes included in E0467

04/04/2019: At this time 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

01/01/2019 R7

Revision History Effective Date: 01/01/2019
NON-MEDICAL NECESSITY COVERAGE AND PAYMENT RULES:
Added: E0447 to Oxygen Content guidelines
CODING GUIDELINES:
Added: E0467 Coding Guidelines
Revised: E1405 and E1406 Coding Guidelines
ICD-10 CODES THAT ARE COVERED:
Added: All diagnosis codes formerly listed in the LCD
ICD-10 CODES THAT ARE NOT COVERED:
Added: Notation excluding all unlisted diagnosis codes from coverage

02/14/2019: At this time 21st Century Cures Act applies to new and revised LCDs which require comment and notice. This revision is to an article that is not a local coverage determination.

08/01/2018 R6

Revision History Effective Date: 08/01/2018
CERTIFICATE OF MEDICAL NECESSITY (CMN):
Removed: Flow rate instructions when answering CMN question 5
MODIFIERS:
Added: GA, GY, GZ, and KX modifier requirement instructions
Added: “Q” modifier instructions

06/07/2018: At this time 21st Century Cures Act applies to new and revised LCDs that restrict coverage, which require comment and notice. This revision is to an article that is not a local coverage determination.

04/01/2018 R5

Revision History Effective Date: 04/01/2018
NON-MEDICAL NECESSITY COVERAGE AND PAYMENT RULES
Oxygen Equipment: Initial 36 months
Added: "the appropriate modifiers (QB or QF) must be used." in paragraph regarding flow rate greater than 4 LPM and also meets requirements for portable oxygen
Added: 42 CFR 410.38(g) language, previously in POLICY SPECIFIC DOCUMENTATION REQUIREMENTS section
CERTIFICATE OF MEDICAL NECESSITY
Added: Flow rate guidelines for beneficiaries who require differing day and night rates
CODING GUIDELINES
Revised: Flow rate modifiers for beneficiaries who require differing day and night rates
Revised: Coding guidelines for E1405 and E1406 to indicate that high flow rate modifiers (QB, QF, QG or QR) must not be used with these two HCPCS codes.

04/19/2018: At this time 21st Century Cures Act applies to new and revised LCDs that restrict coverage, which require comment and notice. This revision is to an  article that is not a local coverage determination.

01/01/2018 R4

Revision History Effective Date: 01/01/2018
NON-MEDICAL NECESSITY COVERAGE AND PAYMENT RULES
Oxygen Equipment: Initial 36 months
Added: "the appropriate modifiers (QB or QF) must be used." in paragraph regarding flow rate greater than 4 LPM and also meets requirements for portable oxygen
Added: 42 CFR 410.38(g) language, previously in POLICY SPECIFIC DOCUMENTATION REQUIREMENTS section
CERTIFICATE OF MEDICAL NECESSITY
Added: Flow rate guidelines for beneficiaries who require differing day and night rates
CODING GUIDELINES
Revised: Flow rate modifiers for beneficiaries who require differing day and night rates
Revised: Coding guidelines for E1405 and E1406 to indicate that high flow rate modifiers (QB, QF, QG or QR) must not be used with these two HCPCS codes.

04/19/2018: At this time 21st Century Cures Act applies to new and revised LCDs that restrict coverage, which require comment and notice. This revision is to an  article that is not a local coverage determination.

01/01/2017 R3 Revision Effective Date: 01/01/2017
POLICY SPECIFIC DOCUMENTATION REQUIREMENTS:
Added: NCD 240.2, Long Term Oxygen Therapy Trails, Cluster Headaches, 42 CFR 410.38(g), Repair, Replacement and CMN requirements
CODING GUIDELINES:
Effective 04/01/2017, modifier QF may be used with portable systems or oxygen.
RELATED LOCAL COVERAGE DOCUMENTS:
Added: LCD-related Standard Documentation Requirements Language Article
07/01/2016 R2 Effective July 1, 2016 oversight for DME MAC Articles is the responsibility of CGS Administrators, LLC 18003 and 17013 and Noridian Healthcare Solutions, LLC 19003 and 16013. No other changes have been made to the Articles.
10/01/2015 R1 Revision Effective Date: 10/31/2014
NON-MEDICAL NECESSITY COVERAGE AND PAYMENT RULES:
Removed: “When required by state law” from ACA new prescription requirements
Revised: Face-to-Face Requirements for treating practitioner
N/A

Associated Documents

Medicare BPM Ch 15.50.2 SAD Determinations
Medicare BPM Ch 15.50.2
Related National Coverage Documents
N/A
SAD Process URL 1
N/A
SAD Process URL 2
N/A
Statutory Requirements URLs
N/A
Rules and Regulations URLs
N/A
CMS Manual Explanations URLs
N/A
Other URLs
N/A
Public Versions
Updated On Effective Dates Status
05/09/2024 04/01/2023 - N/A Currently in Effect View
03/15/2024 04/01/2023 - N/A Superseded View
04/14/2023 04/01/2023 - N/A Superseded View
02/16/2023 04/01/2023 - N/A Superseded You are here
Some older versions have been archived. Please visit the MCD Archive Site to retrieve them.

Keywords

N/A